Pennsylvania has 2,475 high-voltage and bulk transmission line segments totalling roughly 13,452 miles, operated by 14 distinct utilities and federal agencies across the Eastern Interconnection (PJM market). Of that total, 2,650 miles are extra-high-voltage (345 kV and above) — the long-distance backbone that moves power across the state.
The interactive map below shows every transmission segment in Pennsylvania from the HIFLD/CISA US Electric Power Transmission Lines dataset, colour-coded by voltage class. Click any line for the operating utility, voltage, status, and the substations it connects. Or browse the national US transmission map to compare Pennsylvania to every other state.
Pennsylvania Electric Transmission Network by the Numbers
- 2,475 total transmission line segments covering ~13,452 miles (HIFLD/CISA dataset)
- 2,650 miles of extra-high-voltage transmission (345 kV and above) — the long-distance backbone
- 14 distinct operators own or operate transmission infrastructure in the state
- Voltage profile: 1,673 miles of 500 kV plus 977 miles of 345 kV
- Grid context: part of the Eastern Interconnection, balanced through PJM
- 1,849 of the segments (about 9,593 miles) are flagged as inferred in the source dataset — routing was estimated rather than digitised from authoritative source data
Voltage Class Breakdown for Pennsylvania
Every transmission segment in the dataset is tagged with a voltage class. Here is how Pennsylvania’s 13,452 miles of line break down:
| Voltage class | Miles | Segments | Share |
|---|---|---|---|
| 500 kV | 1,673 | 65 | 12.4% |
| 345 kV | 977 | 35 | 7.3% |
| 220 – 287 kV | 2,944 | 351 | 21.9% |
| 100 – 161 kV | 4,432 | 799 | 32.9% |
| Under 100 kV | 2,056 | 800 | 15.3% |
| Voltage not reported | 1,370 | 425 | 10.2% |
Top Transmission Operators in Pennsylvania
Ppl Electric Utilities is the largest transmission operator in Pennsylvania with 3,598 miles of line — about 26.7% of the state total. The top four operators (Ppl Electric Utilities, Pennsylvania Electric, West Penn Power, Peco Energy) control about 60.5% of Pennsylvania’s transmission mileage between them.
| Rank | Operator | Line miles | Share |
|---|---|---|---|
| 1 | Ppl Electric Utilities | 3,598 | 26.7% |
| 2 | Pennsylvania Electric | 2,021 | 15.0% |
| 3 | West Penn Power | 1,554 | 11.6% |
| 4 | Peco Energy | 970 | 7.2% |
| 5 | Metropolitan Edison | 762 | 5.7% |
| 6 | Duquesne Light | 645 | 4.8% |
| 7 | American Transmission Systems | 186 | 1.4% |
| 8 | Monongahela Power | 113 | 0.8% |
| 9 | The Potomac Edison | 75 | 0.6% |
| 10 | Ugi Utilities | 57 | 0.4% |
Most-Connected Substations in Pennsylvania
These substations have the highest number of incoming and outgoing transmission line connections in the HIFLD dataset — effectively the busiest hubs in the Pennsylvania grid.
| Rank | Substation | Line connections |
|---|---|---|
| 1 | Siegfried | 21 |
| 2 | Dravosburg | 19 |
| 3 | Middletown Junction | 19 |
| 4 | Sunbury | 18 |
| 5 | Martins Creek | 16 |
| 6 | Peach Bottom | 16 |
| 7 | Hosensack | 15 |
| 8 | South Akron | 14 |
| 9 | Quarry | 13 |
| 10 | Wescosville | 13 |
Pennsylvania’s Longest 500 kV and HVDC Corridors
These are the longest individual EHV (extra-high-voltage) and HVDC line segments in Pennsylvania — the inter-regional transmission spine of the state.
| Corridor | Owner | Voltage | Miles |
|---|---|---|---|
| Conemaugh — Juniata | Unknown owner | 500 kV | 122 |
| Keystone — Juniata | Unknown owner | 500 kV | 118 |
| Unknown123462 — Conemaugh | Unknown owner | 500 kV | 112 |
| Alburtis — Juniata | Ppl Electric Utilities Corp | 500 kV | 88 |
| Wylie Ridge — Harrison | Monongahela Power Co | 500 kV | 79 |
| Unknown132619 — Lackawanna | Unknown owner | 500 kV | 78 |
| Unknown123487 — Mount Storm | Unknown owner | 500 kV | 76 |
| Hosensack (500 Kv Sub) — Three Mile Island | Unknown owner | 500 kV | 75 |
Data Sources and Caveats
Transmission line geometry and attributes come from the HIFLD/CISA US Electric Power Transmission Lines public dataset. Per-state stats on this page are computed by intersecting that dataset with the Pennsylvania state polygon (Esri USA States Generalized Boundaries) and summing the intersected segments using haversine distance on the source line geometries. The dataset only covers transmission infrastructure (typically >= 35 kV); residential distribution wiring is not included. Some segments crossing the state boundary appear in both states’ totals.
Compare Pennsylvania to Other States
Use the national US transmission lines map to compare Pennsylvania’s grid to every other state — including total mileage, operator concentration, and EHV backbone share.